BOM Portal Consolidated BOM Mode

참고

사용가능한 기능들은 Altium 제품 레벨에 따라 다릅니다. 논의하셨던 기능이 소프트웨어에 없다면, Altium 영업에 문의하셔서 자세한 내용을 확인해주세요.

The BOM Portal’s Consolidated BOM mode allows you to create a procurement-orientated BOM document from multiple engineering BOMs, which unifies the parts requirements for delivering a complete product – typically based on multiple PCBs, modules, or functional sub-sections. It replaces the need to aggregate multiple BOM lists through spreadsheets or other manual means while calculating parts quantities for favorable supplier price breaks, rationalizing equivalent component choices, and generating Purchase Orders or RFQs (Request For Quote).

With a Consolidated BOM, the parts from all included BOMs are automatically mapped, totaled, combined when identical, and represented in the cumulative order listing. You also can manually increase a part’s order quantity to exploit a supplier price break point, and merge acceptably equivalent parts into one ‘consolidated’ BOM line entry.

Note that the Consolidated BOM feature is available when the BOM Portal application is enabled for your Workspace.

If using the Altium BOM Editor to work with BOM documents, any existing Consolidated BOM documents are read-only.

The procurement-orientated Consolidated BOM format includes multiple BOM releases with the ability to consolidate equivalent components and manipulate purchase quantities. The procurement-orientated Consolidated BOM format includes multiple BOM releases with the ability to consolidate equivalent components and manipulate purchase quantities.

Use the Create Consolidated BOM option from the button menu on the Projects page to configure a new Consolidated BOM document in the Create Consolidated BOM dialog window. You can add multiple BOMs from existing Managed BOMs and/or Design Projects to create the combined Consolidated BOM, and specify production quantities for the included BOMs or the entire Consolidated BOM. The added BOM data can be from a BOM or Project in its current state – a WIP data snapshot – or from existing BOM/Project Releases.

To create a new Consolidated BOM document choose the Create Consolidated BOM option from the drop-down menu on the Workspace Projects page.

In the following Create Consolidated BOM dialog window click the  button to begin the process of choosing BOM data sources that will be included.

Expand the hierarchy of available Design Projects and Managed BOMs in the Select BOM sources to Consolidate window to locate the desired BOM data sources. Open the Properties pane () for information on the selected item – you can open the Project, BOM, or Release by clicking on its name.

Check the BOM sources to be included in the Consolidate BOM. In this example, the primary WIP sources of a Managed BOM and a Project variation have been selected. The Consolidated BOM will provide an alert notification if a WIP source is subsequently updated.

You also can choose available Releases to populate the Consolidated BOM. Here, Releases for both a Managed BOM and a Project have been selected. Click to confirm the data source selections. 

Back in the Create Consolidated BOM window you can inspect the list of included BOMs, multiply the number of source BOMs parts (Production Quantity), edit the proposed Consolidated BOM Name and add an optional Description. Click to complete the process.

The resulting Consolidated BOM document is added to the Projects listing, with details included in the Information pane on the right. Click on its name to open immediately.

A Consolidated BOM shares most functions and features available to a Managed BOM in the BOM Portal. Notable examples of this are:

  • The ability to add and remove individual BOM entries with the Add Row () and Remove Row () functions – see the BOM Portal's List Features.

  • Access to a BOM item’s detailed information through the Info pane () – see the BOM Portal Information Pane.

  • The ability to add assignable Comments to BOM line items from the Comments and Task pane () – see BOM Portal  Comments.

A Consolidated BOM also has several important feature differences from a Managed BOM to accommodate its procurement-orientated focus:

  • Manufacturer Part Number references are not editable because they are specified in the source Managed BOM or Design Project.

  • A unique Source BOMs column is included that provides links to the selected part’s source BOM and their applicable Designator references.

  • A unique Consolidated Parts column is included which references any individual part entries that have been combined into a single BOM line.

  • A unique Category column is included that allows component part entries to be organized by Type for equivalent part consolidation purposes.

  • The Extra Qty and Total Qty columns are automatically enabled to allow the manipulation of order quantities for favorable purchasing outcomes. Note that these columns also are available in Managed BOMs.

  • An opened Consolidated BOM will automatically detect if an included WIP BOM source (as opposed a static Release) has been updated – a newer Revision exists. Select Update BOM to incorporate the changes into the Consolidated BOM.

BOM Sources and Parts Copy Link Copied

The Source BOMs column data in each Consolidated BOM line entry includes references to that component part in one or more of the source BOMs, which can be Managed BOMs, Projects, or their releases. The cell entry provides source part information and a link to the source BOM/Project/Release itself.

Hover over a primary BOM source reference to view the part name and its associated Designators. Click on the source BOM name to view that BOM sorce in a new browser tab.

Select an additional BOM source reference ('and <x> more') to view the part name and its associated Designators.

Click on the additional BOM source part information to view the source BOM in a new browser tab.

Parts Consolidation Copy Link Copied

While the Consolidated BOM automatically collates identical parts from the source BOMs into a single quantity-adjusted line entry, there are likely to be other equivalent part entries that can be combined – such as the same functional parts from multiple manufacturers. This situation can be addressed with the Consolidated BOM’s Manual Parts Consolidation feature.

The parts consolidation feature and its associated column data allow notionally equivalent component parts entries to be combined into a single BOM line entry with a recalculated Quantity parameter. Invoked from the button, the parts consolidation process also creates a combined parts information entry in the Consolidated Parts column cell. This process is expedited by the Consolidated BOM’s Category column, which can be set to filter for specific component Types – say Capacitors – and then the parts Parameters column reordered to easily compare like component entries.

The easiest way to locate BOM parts suitable for consolidation is to first filter the BOM list to show a specific part Type by selecting the Filter option () from the Category column header.

In the Category filter drop-down list, deselect the All option and then check the desired Component Type (Capacitor, Resistor, etc) to constrain the BOM list to that part category.

Parts with similar parameters can be gathered together in the listing by ordering the BOM entries by the Parameters column.

Click on the header’s arrow icon ( ) to toggle the order between ascending, descending and ‘no order’ (when the arrow is white rather than blue).

To begin consolidating BOM line entries into a single entry select the Manual Consolidation Mode button (), which enables a checklist column at the beginning of each BOM line.

Locate and check the BOM lines you would like to consolidate. In this example, the parts offer equivalent parameters but with a different voltage rating.

In the upper parts consolidation drop-down menu select the preferred component to become the single consolidated BOM entry. It is the higher rated part in this example, but it could be decided by other crucial factors such as better pricing or stock levels (as available in the drop-down information).

Click the button to confirm the process and create the new single-line BOM entry.

The new BOM line entry is marked as updated (by the leading yellow dot) and an active information entry is added in the Consolidated Parts column. Note that the yellow update dot will not appear when different Part Choices from the same Workspace component have been consolidated.

Select the Consolidated Parts cell entry to view a list of parts that have been consolidated into the new BOM line part entry – one other in this example. Click on the part to open its source BOM source in a new browser tab, or use the icon to undo its consolidation (see below).

Any number of BOM line entries can be consolidated into a single entry by selecting them in the checklist and choosing the preferred component part for the consolidated entry, as decided from the parametric data included for each part option.

The number of parts that have been consolidated is indicated by the Consolidated Parts column entry, which will also list the other parts that have been absorbed by the single line. Click on a listed part to open its BOM source in a new browser tab, or use the icon to undo its consolidation (see below).

Once all possible parts have been consolidated for the selected component Category, you can click the button to exit Consolidated mode, or re-filter the BOM Category list to focus on another part type. Note the Reset Filters option at the top of the BOM listing.

A part that has been consolidated into a single entry can be restored to its individual BOM line using the icon in its host Consolidated Part entry. This effectively extracts that part from consolidation back into its own BOM line entry.

Managing Part Quantities Copy Link Copied

Both Consolidated BOM and Managed BOM documents include an Extra Qty column that allows you to increase the number of parts that will be ordered. Managing the part order quantity can be used to take advantage of supplier price break points, accommodate expected component wastage, anticipate further production, and other procurement considerations.

Entering a value in the Extra Qty column will proportionally increase the total figure in the Total Qty column (BOM Qty + Extra Qty) and consequently revise the automated Order List and parts Supplier solutions where possible.

A BOM line example where 2 component parts are required by the source BOM (BOM Qty) resulting in a supplier order total of 2 parts for the Consolidated BOM (Total Qty).

This results in a supplier order of 2 parts (Supplier Order Quantity) priced at the single item rate, and a stated purchasing cost for each component part (Unit Price).

The Consolidated BOM’s Extra Qty column allows the total ordering quantity to be adjusted for each BOM line entry to take advantage of supplier offers such as beneficial price break points.

For this example, the number of ordered parts is increased by adding 4 additional items in the Extra Qty cell.

The Consolidated BOM automatically adjusts the total number of parts (Total Qty) to accommodate the Extra Qty entry, resulting in an order requirement of 6 parts.

The system automatically applies a revised, optimal ordering solution (the Order List entry) in response to the increased parts order (Supplier Order Quantity). An ordering price break for 10 items is now used, leading to a substantial Unit Price reduction (around 50%) and 4 unused components (Surplus).

Extra quantities also can be added automatically using the Autofill Extra Quantity feature available from the BOM options menu (). See Autofill Extra Quantity feature for related details. With a Consolidated BOM this includes an additional Multiply quantity by number of unique source BOMs option. When checked, the calculated Extra Qty figure is multiplied by the number of Managed BOM documents incorporated in the Consolidated BOM.

Consolidated BOM Settings Copy Link Copied

The Consolidated BOM includes additional options in the BOM Settings window that allow you to add further source BOMs and increase the number of individual source BOMs included. In both cases the Consolidated BOM will automatically amalgamate identical component parts and adjust quantities accordingly.

To add, remove, or alter the quantity of source BOM instances, select the Consolidated BOM tab in the BOM Settings window accessed from the upper menu. Use the icon to remove a BOM source entry.

The number of source BOM instances in the Consolidated BOM is changed by editing the entry’s Production Quantity field. The sum of parts contributed by the source BOM will be multiplied by this quantity figure.

Select the Add BOMs option to locate and add further source BOMs to the Consolidated BOM.

Locate and select the desired BOM data source to add by expanding the hierarchy of available Design Projects and Managed BOMs (and their releases) in the Select BOM sources to Consolidate window.

The addition of source BOM data and changed quantities will be reflected in the source BOM listing. Click to confirm the changes. See the BOM Settings section above for more information on the available BOM settings options.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
참고